1.18.30.23 Preview, 1.18.30.22 Beta, 1.18.0.27 Beta, 1.18.0.24 Beta, 1.18.0.23 Beta, 1.18.0.22 Beta, 1.17.40.21 Beta, 1.17.40.20 Beta, 1.17.11 Hotfix, 1.17.10, 1.17.10.20 Beta, 1.16.230.56 Beta, 1.16.230.54 Beta, 1.16.230.52 Beta, 1.16.230.50 Beta, 1.16.220.52 Beta, 1.16.220.51 Beta, 1.16.220.50 Beta, 1.16.210.61 Beta, 1.16.210.60 Beta, 1.16.210.59 Beta, 1.16.210.58 Beta, 1.16.210.57 Beta, 1.16.210.56 Beta, 1.17.32, 1.17.33, 1.17.34, 1.17.40, 1.18.0.25 Beta, 1.17.41 Hotfix, 1.18.2 Hotfix, 1.18.30.21 Preview, 1.18.30.20 Beta, 1.18.12 Hotfix
-
Confirmed
-
Multiple
-
436445
This bug report is a parity issue with Java.
Summary:
The Sculk Sensor does not respond to opening and closing:
- Trapdoors
- Doors
- Fence Gate
- Piston Activation
Steps to reproduce:
- Place the Sculk Sensor in Bedrock and Java version.
- Place the above blocks side by side.
- Interact with placed blocks (open/close).
- Compare the result of the two platforms.
Expected results:
The Sculk Sensor will respond to interactions with placed blocks.
Observed results:
The Sculk Sensor does not respond to interactions with placed blocks in the Bedrock version.
Notes:
Since the Sculk Sensor in the latest version does not yet respond to pressing a button, you can simply activate the piston by pressing a button. When this is corrected (the Sculk Sensor will react to pressing the button), it will be necessary to conduct a redstone signal from the piston to the area where the Sculk Sensor will not pick up sounds (currently 8 blocks).
- is duplicated by
-
BDS-11971 sculk sensor not registering pistons trapdoor sounds
- Resolved
-
BDS-12889 Trapdoor interaction with Skulk sensor
- Resolved
-
BDS-15907 Sculk Sensor Doesn't Detect Sound Vibration Door, Trapdoor, Bell
- Resolved
-
MCPE-116828 Skulk sensor issues
- Resolved
-
MCPE-121626 When a mob or player walks near a shulk sensors it activates but if you where to open a door or throw a snowball nothing would happen
- Resolved
-
MCPE-122294 Sound problem with sensor
- Resolved
-
MCPE-123076 Sculk sensors does not work
- Resolved
-
MCPE-135518 sculk sensor does not work with doors or trapdoors
- Resolved
-
MCPE-135539 Sculk sensors do not detect pistons activating
- Resolved
-
MCPE-141426 The sculk sensors do not work with wool occlusion and do not detect pistons levers trapdoors
- Resolved
-
MCPE-145705 Sculk Sensor doesn't work properly.
- Resolved
-
MCPE-146791 (Java parity) sculk sensor does not vibrate with doors ,trapdoors and fence gates
- Resolved
-
MCPE-150784 Skulk sensors
- Resolved
-
MCPE-152987 Sculk Sensors aren’t activated by trapdoors moving
- Resolved